Clinlab Navigator

Serum to Ascites Albumin Gradient

The application of Light's criteria for classifying transudates and exudates is often misleading when applied to peritoneal fluid (ascites). The measurement of albumin in ascitic fluid as a surrogate marker of portal hypertension has largely replaced the practice of distinguishing transudates from exudates. Calculation of a serum to ascites albumin gradient (SAAG) is a more physiologically appropriate test.  It is calculated as the serum albumin concentration minus the peritoneal fluid albumin.  A high gradient (>1.1 g/dL) indicates ascites related to portal hypertension, usually due to cirrhosis. Increased hydrostatic pressure within hepatic portal veins forces water, but not large proteins such as albumin, into the peritoneal cavity. Heart failure can also produce a high gradient. A low gradient <1.1 g/dL is usually associated with peritoneal seeding by cancer, tuberculosis and other infections. 